Or, create a printer configuration and see if it works. Supported Network Protocols to see if TCP/IP LPR/LPD, Port 9100, IPP, or SNMP is listed. Refer to the printer hardware documentation or visit the printer manufacturer's website to locate the printer's specifications to make the determination if it will work with the IBM i.Įmulation or Printer Languages, or search on PCL.
This document is updated on an as needed basis. IBM support does not actively search for information about new or different printers. This document is not updated on a regular basis. Note: This document was formerly titled Support for ASCII Printers from Canon. N1019698: Printer Model Settings for Host Print Transform (HPT) N1019605: Information on Printers from Various Manufacturers For information on printers from other manufacturers, please refer to the following documents: It also indicates whether each printer model is likely to work when printing from the IBM System i products using LPR, PJL, SNMP, IPP, or a PC5250 printer session. Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR.This document contains information on the capabilities that are supported on printer hardware from Canon. Causes: The fixing film unit is faulty (i.e., the main thermistor (TH1) has poor contact or has an open circuit or, the fixing heater is faulty).Description: The main thermistor reading is lower than 140C when paper is moved.Fixing film unit, DC controller PCB Try replacing the fixing film unit. Wiring Is the wiring from the DC controller PCB to the fixing film unit normal? NO: Correct the wiring. Does the fixing heater operate? NO: See “The fixing heater fails to operate.” 2. Thereafter, turn off and then on the power switch. State Turn on the power switch, and clear E002/E003. Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>FCLEAR>ERR. Causes: The fixing film unit is faulty (i.e., the main thermistor TH1 has poor contact, or the fixing heater is faulty).has exceeded 160C, but does not reach 165C within 1 sec thereafter has exceeded 140C, but does not reach 150C within 1 sec thereafter. Has exceeded 100C, but does not reach 115C within 1 sec thereafter. Description: The temperature of the fixing film is as follows:.Description: The sub thermistor detects about 295C or higher.Description: The main thermistor or the sub thermistor detects overheating (hardware circuit detection).
Main power supply PCB, DC controller PCB Try replacing the main power supply PCB. If the thermistor has a short circuit, the indication in service mode (COPIER>DISPLAY>ANALOG) will be as follows from the start: FIXC= 250☌ for the main thermistor FIX-E=310☌ for the sub thermistor. Is it 0 W (short circuit)? YES: The thermistor has a short circuit.